New1a.gif (2524 bytes)Autodialer Feature for the MetaEye Ea VideophoneNew1a.gif (2524 bytes)

autodi2.jpg (16965 bytes)autodi3.jpg (11188 bytes)

New* MetaEye  AE Autodialing Function

The Autodialing function enables MetaEye AE to automatically dial out two different phone numbers and reach security centers, you can set up an ID (8-digit) at each remote site for the security center to identify the call-from site.

An alarm event starts with a pulse** generated by Sensor, MetaEye AE at Site #1 is triggered and it will alternate dialing between Center A and B before a successful connection. The connection period can be up to 18 min. based on the Timer setting of MetaEye AE at Center A (if Center A answers the call before Center B does)
If Center B answers the call first, you can change the status*** of DO#1 output port from open-circuited to close-circuited as the signal to reset the alarm system and end the event.

* Available with version 2.1 firmware/hardware or above

** 9 - 24 VDC required, must be latched at high level before the event ends
*** DO#1 stays open-circuited before the autodialing event is terminated by Timer or "CONTROL"->"ON" selection

 

ad1.gif (13836 bytes)
** NEW MetaEye AE I/O Box

With the I/O box connected to MetaEye AE, you will be able to turn on/off two electric devices (up to 10A/250VAC each port) at the remote site. The status of all I/O ports can also be monitored clearly through LED indicators at the front panel.

 

io1.gif (13999 bytes)

ioap1.gif (18400 bytes)
Control Input Dry contactor
Control Output 10A/250VAC, 30VDC max.
N.O./N.C./COM
Power Source DC 5V +/- 10%
Power Consumption 2.5 W